Volumetric Infusion Pump
■ Clear, Easier and Faster
– Touchable Keypad
* Easy and Fast way to setup
– Various Displays
* FND displays numerical data clearly.
– User Friendly and Ergonomic Design
* Simple setup process makes user feels
comfortable and variety display makes
user gets complete information at one glance.
* Proper weight & superb grip for easy carriage.
■ Alarm(Visual & Audio) Function.
– Door Open
– Air Bubble Sensing
– Low Battery
– Infusion Completion
– Occlusion
* 1:100~400 mmHg,
5: 300~700 mmHg,
9: 600 ~ 1 000 mmHg
– Drop Error Sensing by Drop Sensor
* Including Empty error
* External Option.
– Device Malfuntion
* Status of equipment and Alarm.
– Start Reminder Alarm
* After Pause Setting Time.
■ Safety Function.
– Keypad Lock – All key don’t work except START and ON/OFF key.
– Door Open.
– Air Sensor.
– Occlusion Sensor
– Drop Sensor
– Nurse Call (Option)
*Each unit can be connected with nurse call system
■ Various Functions
– Self Testing – Every time unit turns on, self testing is proceeded.
– K.V.O (Keep Open Vein) – When the infused volume has been reached,
flow rate turns into K.V.O rate automatically.
– Retain Memory – Last setting value will be retained.
– Remaining Time Display.
– Alarm Repeat
– Purge – Faster infusion than normal state.
– Buzzer Level – 9 steps.
– Titration(Changing the Flow Rate during infusion)
– Micro / Macro Control
– Infusion Setup – Flow rate / Infused volume / Infusion time.
– Interface ( Communcation) – USB
– Less Noise (Micro Stepping Motor)
– Easy Replacement of Battery.
– CE, ISO13485, KFDA certified.
Product Name |
Volumetric Infusion Pump |
|
Model Name |
INFU-Z 2000 |
|
Pump System |
Peristaltic Finger System |
|
Control Mode |
Volumetric Control |
|
Flow Range |
0.1 ~ 1200ml/h |
|
Volume Range |
1 ~ 9999ml |
|
K.V.O. |
OFF, 0.1 m/h, 1~5 ml/h |
|
Bolus Rate |
1 ~ 1200ml/h |
|
Occlusion Limit |
1: 100~400mmHg, 5: 300~700mmHg, 9: 600~1000mmHg |
|
Accuracy |
±5% |
|
Display |
FND 7 Segments |
|
Battery |
Li-ion Rechargeable Battery |
|
– 2200mA/h, 10.8V |
||
– Operating Time: approx. 5 hours (Flow Rate 25ml/h) |
||
– Recharging Time: approx. 8 hours |
||
Electric Shock Protection |
Class I, Type CF |
|
Waterproof |
IPX2 Standard |
|
Power Input |
AC 100 ~ 240 VAC, 50 ~ 60Hz (Fuse : 250V, T1.6A), |
|
Power Consumption |
40VA |
|
External Source |
DC 12~18V |
|
Weight |
2.7 Kg |
|
Size(W×H×D) |
198mm×115mm×203 mm |
|
Interface |
USB |
|
Macro/Micro |
Total Volume |
Micro: 0.1~999.9ml (0.1ml step) 1000~9999ml (1ml step) |
Macro : 1~9999 ml (1ml step) |
||
Flow Rate |
Micro : 0.1~999.9 ml/h (0.1ml step) 1000~1200ml /h (1ml step) |
|
Macro : 1200 ml/h |
||
History Log |
2000 events |
|
Using Environment |
Operation Temperature: 10°C to 40°C |
|
Storage Temperature: -10°C to 60°C |
||
Humidity: 20% to 95% RH |
||
Operation Altitude: 70 kpa ~ 106 kPa |
||
Accessory |
Operation Manual (English), AC Power Cable, |
|
Drop Sensor (External Option, drop rate range depends on IV sets) |
Image | Code No. | Name | Specification |
---|---|---|---|
DS01-01R | Drop sensor | Infrared Detector |