PAVO Vital Sign Monitor

SKU
Price

aXcent PAVO Vital Sign Monitor

8” color TFT LCD Screen (touch screen optional)
Portable, lightweight and sturdy design
Flexible parameters configuration for different clinical environments
Rechargeable Li-ion Battery (up to 12 hours uninterruptable work)
Big font and font color display setting
Spot-check and continuous monitoring mode

Features
• 8” color TFT LCD Screen (touch screen optional)
• Portable, lightweight and sturdy design
• Flexible parameters configuration for different clinical environments
• Rechargeable Li-ion Battery (up to 12 hours uninterruptable work)
• Big font and font color display setting
• Spot-check and continuous monitoring mode
• Selectable for Adult, Pediatric and Neonatal patients
• Wired/Wireless CMS, support HL7 protocol to HIS
• Barcode scanner support
• Thermal recorder support
• Graphical & tabular trend review
• 48 hours holographic wave review for each patient (stored in SD card)
Display
8” color TFT LCD Screen, resolution: 800 x 600

ECG
Lead type
3-lead: I, II, III
5-lead: I, II, III, aVR, aVL, aVF, V
Display sensitivity:
2.5 mm/mV (×0.25), 5 mm/mV (×0.5),
10 mm/mV (×1.0), 20 mm/mV (×2.0)
Wave sweep speed: 6.25 mm/s, 12.5 mm/s,
25 mm/s, 50 mm/s
Bandwidth
Diagnostic mode: 0.05Hz~100Hz
Monitor mode: 0.5Hz~40Hz
Surgery mode: 1Hz~20Hz
Strong filter mode: 5Hz~20Hz CMRR
>100dB
Notch: 50/60 Hz notch filter can be set to
on or off
Differential input impedance >5 MΩ
Electrode polarization voltage range: ±400 mV
Baseline recovery time <3 s after defibrillation
(in monitor and surgery mode)
Calibration signal: 1 mV (peak – peak),
accuracy ±3%

RESP
Measurement method: Thoracic electrical
bioimpedance
Rate: 0 – 150 bpm
Measuring lead: Lead I, II
Wave gain: ×0.25, ×0.5, ×1, ×2
Respiratory impedance range: 0.5-5 Ω
Baseline impedance: 500-4000 Ω
Gain: 10 grades
Scan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s

TEMP
Measurement method: Thermistor
Measuring range: 5~50 °C (41~122 °F)
Resolution: 0.1 °C
Measurement accuracy: ±0.1 °C

Recorder (optional)
Built-in, Thermal dot array
Horizontal resolution: 16 dots/mm (25 mm/s
paper speed)
Vertical resolution: 8 dots/mm
Paper speed: 25 mm/s, 50 mm/s
Number of waveform channels: 3

Technical Specifications
For Out-Patient Department, Spot-check, Transport,
Ward and other Basic Monitoring.
Configuration Optional
SpO2 + NIBP, Li-ion battery Masimo/Nellcor SpO2, Quick Temp,
Barcode scanner
SpO2+NIBP+ECG+TEMP,
Li-ion battery
Masimo/Nellcor SpO2, EtCO2, Quick Temp,
Barcode scanner, Thermal Recorder

NIBP
Measurement method: Automatic
oscillometric method
Operating mode: Manual, automatic,
continuous
Measurement unit: mmHg/kPa selectable
Typical measurement time: 20~40 s
Measurement type: Systolic, Diastolic, Mean
Measurement range (mmHg)
Range of Systolic pressure: Adult 40-270
Pediatric 40-230
Neonatal 40-135
Range of Diastolic pressure: Adult 10-210
Pediatric 10-150
Neonatal 10-100
Range of Mean pressure: Adult 20-230
Pediatric 20-165
Neonatal 20-110
Measurement accuracy
Maximum average error: ±5 mmHg
Maximum standard deviation: 8 mmHg
Resolution: 1 mmHg
Interval: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120,
180, 240, 480 minutes
Overpressure protection: Software and
hardware, double safety protection
Cuff pressure range: 0-280 mmHg
Standard SpO2
Measurement range: 0-100%
Resolution: 1%
Accuracy: ±2% (70-100%, Adult/Pediatric);
±3% (70-100%, Neonate);
0-69%, unspecified
Refreshing Rate: 1s
Masimo SpO2 (optional)
Measurement range: 0-100%
Resolution: 1%
Accuracy: ±2% (70-100%, Adult/Pediatric),
non-motion, low
±3% (70-100%, Neonate,
non-motion);
±3% (70-100%, motion);
0-69%, unspecified
Refreshing Rate: 1s
PAVO Vital Sign Monitor
Technical Specifications
Portable Design Touch Screen
(Optional)
Quick Temp
(Infrared Ear Thermometer)
Infrared Ear Thermometer (optional)
Displayed range: 34~42.2 °C (93.2~108 F°)
Operation ambient temperature range:
10~40 °C (50~104 °F)
Accuracy for displayed temperature range:
≥35 °C (95.9 °F) ~ ≤42.2 °C (107.6 °F) range
±0.2 °C (0.4 °F)
<35 °C (95.9 °F) ~ ≥34 °C (93.2 °F) range
±0.3 °C (0.5 °F)
Phasein IRMA™ Sidestream CO2 (optional)
Warm-up time: Full accuracy within
10 seconds
Sampling flow rate: 50 ml/min (+/-10/min)
Accuracy: ± (0.2% +2% of the reading)
Measurement Range: 0 -15%
Rise time: 200 ms, typical at 50 ml/min
flow rate
Total response time: within 3 seconds
(with 2m Momoline sampling line)
AWRR Range: 0-150 bpm
AWRR Accuracy: ±1 breath
Phasein IRMA™ Mainstream CO2 (optional)
Measurement Range: 0-15%
Warm-up time: Full accuracy within 10 seconds
Accuracy: ± (0.2% +2% of the reading)
AWRR Range: 0-150 bpm
AWRR Accuracy: ±1 breath
Operation Environment
Power: AC 100-250 V, 50/60 Hz
Temperature: 0-40 °C
Humidity: 15-85%
Patient Range: Adult, Pediatric, Neonate
Battery backup: Standard 4-5 hrs (2.600 mAh),
optional 8-10 hrs (5.200 mAh) or 12-15 hrs
(7.800 mAh)